Home Technical data of cleanroom Purification level of design steps for decorating clean rooms, dust-free workshops, cleanrooms, and purification rooms

Purification level of design steps for decorating clean rooms, dust-free workshops, cleanrooms, and purification rooms

Purification level of design steps for decorating clean rooms, dust-free workshops, cleanrooms, and purification rooms

Quick Answer: 当我做好Clean Factory的平面Planning后就要定义好Dust-Free Workshop的Cleanliness。Cleanliness是什么意思呢?Cleanliness的等级怎么去划分?目前Cleanliness按漂亮国联邦标准,常见的级别基本上有5个等级,Class 100、Class 1,000、

After I have completed the floor plan of the cleanroom, I need to define the cleanliness level of the cleanroom. What does cleanliness mean? How to classify the cleanliness level?

Currently, according to the federal standards of the United States, there are generally five levels of cleanliness: hundred, thousand, ten thousand, ten thousand, and one hundred thousand. As for levels one, two, three, five, and ten We do not conduct analysis.

Many people believe that a cleanroom is dust-free, but this is a misconception. So how do we define the purification level? Simply put, it is to give a certain range of dust in the air; Number” Come out!! You heard correctly, it's counting. This number is not something elementary school students use their fingers to count one, two, three... Instead, a dust particle counter is used. Surprisingly, it was able to“ Count it out; So we can divide the purification level according to the counted quantity. What are the parameters for a hundred level purification level? According to the standard, we can know that m³ /0.5μm/≤ 3520pc ! The meaning is that each cubic space contains less than 3520 dust particles of 0.5 microns, with a thousand level of 35200 and ten thousand level of 352000... The following figure shows the standard list of purification levels

Purification level

So how do we choose the purification level?

1. According to relevant GB national standard documents, different GBs in the industry have mandatory regulations for you. For example, the medical device clean room is rated as 100000 level, and the laboratory part is rated as 10000 level or above. As for where these will go, it also depends on what products are produced.

Secondly, according to the needs of one's own product, cleanliness is an important indicator that affects product yield. How much cleanliness can improve yield? This parameter needs to be obtained through industry experience and multiple experiments, and can only be judged by consulting relevant technical personnel in the same industry or based on our successful cases in clean rooms. Taking the mobile phone industry as an example: the bonding process requires achieving a hundred level purification!

The following picture is a real-life shot of our company's Class 100 workshop:

The determination of the purification level of thedust particle counter is not only based on particles of 0.5 microns, but usually also on particles of 5 microns. For particles above 5 microns, manual cleaning is required. This is also an important parameter for determining whether a cleanroom is used as a cleanroom standard

The next article will introduce the calculation of air volume in the design steps of building clean rooms, dust-free workshops, clean rooms, and purification rooms

If you think this article is useful, please give it a thumbs up, like it, and share it! If you feel that the editor in chief needs to use so much brainpower and energy to manually code words, just raise your index finger and follow!!